Home > MUA Screw Cross-Platform Fit Guide

MUA Screw Cross-Platform Fit Guide

MUA Screw Cross-Platform Fit Guide

The Rosen Screw 1.4mm is the direct-connect multi unit abutment screw described here: a titanium Gr5 ELI fastener driven with a 1.25 mm hex tool and torqued to 20 Ncm. It answers a practical question for restorative teams — whether one part can serve a mixed catalogue that includes a Neodent GM abutment platform alongside the other listed systems. Below you will find the four hard specifications, the full platform list, the driver and torque protocol, and a decision table that shows when this screw is not the right component.

Rosen Screw 1.4mm MUA Screw Dental Implant Titanium Screw Multi unit Screw for full-arch Compatible Neodent GM Hiossen 3i Adin Biohorizons Dentsply Dess Medentika Keystone Osstem Megagen Nobel Biocare Straumann Zimmer Thommen Medical

Rosen Screw 1.4mm at a Glance

One part number carries four hard specifications and a quantity ladder that runs from a single spare to a 100-piece stock box. Those four numbers decide whether the part drops into your workflow at all.

Rosen Screw 1.4mm MUA Screw Dental Implant Titanium Screw Multi unit Screw for full-arch Compatible Neodent GM Hiossen 3i Adin Biohorizons Dentsply Dess Medentika Keystone Osstem Megagen Nobel Biocare Straumann Zimmer Thommen Medical

The screw seats directly into the multi-unit abutment — no titanium base sits between the two components.

Rosen Screw® 1.4mm (For 1.25 Hex Driver)


Pick the quantity tier before you order

1 Pc10 Pcs50 Pcs100 Pcs


The product page asks you to choose an option before the cart unlocks, and the displayed price moves with the tier selected. Single pieces suit chairside replacement; 50 and 100-piece tiers are aimed at labs and distributors holding stock.

26 Listed Implant Systems, Four Scan Groups

Every platform below is named on the product page. The four groups exist only to make the list scannable — they are not a statement that two brands share an identical interface. Confirm driver seating on the platform you actually stock before a full-arch case is booked.

26 systems listed
Swipe to see all columns →
Platform as listed Product-page status Verify before ordering
Group 1 — Mini-conical and GM-type interfaces (4 platforms)
Neodent mini conical Listed compatible Seat a trial screw and confirm the 1.25 mm hex driver engages fully.
Dentis ICX Listed compatible Check the screw against your current MUA stack before stocking a box.
IPS Medentis Medical (ICX) Listed compatible Confirm at order — platform variants can differ between production runs.
Medentika Listed compatible Run one case before committing to the 100-piece tier.
Group 2 — Internal-connection platforms, set A (8 platforms)
Straumann Listed compatible Seat a trial screw and confirm the 1.25 mm hex driver engages fully.
Nobel Biocare Listed compatible Check the screw against your current MUA stack before stocking a box.
Astra Listed compatible Confirm at order — platform variants can differ between production runs.
Zimmer Listed compatible Run one case before committing to the 100-piece tier.
3i Listed compatible Seat a trial screw and confirm the 1.25 mm hex driver engages fully.
Biohorizons Listed compatible Check the screw against your current MUA stack before stocking a box.
Keystone Listed compatible Confirm at order — platform variants can differ between production runs.
Thommen Medical Listed compatible Run one case before committing to the 100-piece tier.
Group 3 — Internal-connection platforms, set B (8 platforms)
Hiossen Listed compatible Seat a trial screw and confirm the 1.25 mm hex driver engages fully.
Osstem Listed compatible Check the screw against your current MUA stack before stocking a box.
Megagen Listed compatible Confirm at order — platform variants can differ between production runs.
Neobiotech Listed compatible Run one case before committing to the 100-piece tier.
GenTek Listed compatible Seat a trial screw and confirm the 1.25 mm hex driver engages fully.
Adin Listed compatible Check the screw against your current MUA stack before stocking a box.
Cortex Listed compatible Confirm at order — platform variants can differ between production runs.
SRL Listed compatible Run one case before committing to the 100-piece tier.
Group 4 — Additional listed platforms (6 platforms)
BlueSkyBio Listed compatible Seat a trial screw and confirm the 1.25 mm hex driver engages fully.
Dess Listed compatible Check the screw against your current MUA stack before stocking a box.
Densply Listed compatible Confirm at order — platform variants can differ between production runs.
ZFX Listed compatible Run one case before committing to the 100-piece tier.
Noris Listed compatible Seat a trial screw and confirm the 1.25 mm hex driver engages fully.
Southern Implants Listed compatible Check the screw against your current MUA stack before stocking a box.

Brand names belong to their respective owners and are used here only to identify the platforms named on the product page. “Listed compatible” means the platform appears in that list — it does not mean this is an original manufacturer part. Seat a trial screw before releasing stock to a clinical account.

What a Mini-Conical / GM Interface Changes About Screw Choice

On a mini-conical abutment interface the retaining screw is the part that carries the abutment’s preload down into the implant. The thread is rarely what buyers get wrong — the driver is.

Rosen Screw 1.4mm hex engagement detail for mini-conical abutment interfaces

The 1.25 mm hex socket is the single contact point between your driver and the screw.

The interface, in plain terms

The product page lists Neodent mini conical among its 26 platforms, alongside Straumann, Nobel Biocare, Hiossen, Osstem, Zimmer and Thommen Medical. A “mini-conical” description — the GM style labelling distributors use for that interface family — describes how the abutment seats on the implant. It says nothing about how the screw is turned, and that is where ordering mistakes happen.

Why the hex engagement is the gating requirement

This screw accepts a 1.25 mm / 0.05" hex driver, and that number is not negotiable. If the driver in your kit is a different size, you cannot deliver the 20 Ncm target cleanly — the tool rocks in the socket, the hex deforms, and the screw becomes the wrong part even though the thread matched. Support staff answering the phone should ask for the driver size before they ask for the implant brand.

Direct connection versus a titanium base

The Rosen Screw 1.4mm is built to connect straight to the multi-unit abutment without a Ti base. That removes one component and one bonding step from the stack. If your restorative design is built around a titanium base instead, read the decision table below — this screw is not the piece that completes that assembly.

Driver: 1.25 mm / 0.05" hex — the only engagement the screw accepts.

Route: direct to the multi-unit abutment. No titanium base required.

Direct-to-MUA Screw or Titanium Base?

Two routes reach the same place, but they are not interchangeable. Read the left column if you want fewer components in the stack; read the right column if your design is already built around a base.

Route A — This part

Rosen Screw 1.4mm, direct to the MUA

ComponentsMulti-unit abutment + Rosen Screw 1.4mm. Nothing between them.
Chair stepsOne driver engagement at 20 Ncm with a 1.25 mm hex tool.
Lab stepsNo titanium base to bond or cement into the structure.
Scan & designOne fewer interface to model; the screw channel is the abutment channel.
Choose this whenYour abutment accepts a direct screw and your kit already carries a 1.25 mm hex driver.
Route B — Different stack

Titanium-base retained structure

ComponentsMulti-unit abutment + titanium base + that base’s own retaining screw.
Chair stepsAn additional component interface to seat and verify before the structure goes down.
Lab stepsAn extra bonding or cementing step between base and framework.
Scan & designThe base geometry enters the design file and the library selection.
Choose this whenYour restorative design, existing inventory or lab protocol is already built around a titanium base.

Decision rule: if your workflow is designed around a titanium base, the Rosen Screw 1.4mm is not the part that completes it. This screw is specified for direct connection to the multi-unit abutment without a Ti base — buying it to sit inside a base assembly means buying the wrong component.

If you are unsure which route your lab is running, send the platform name and your current component list to the team before you order a 50 or 100-piece tier.

Torque and Driver Protocol: 20 Ncm on a 1.25 mm Hex

The specification is simple; the failure points are all in the seating. Work through the five steps in order and the screw behaves the way the data sheet says it will.

Target torque: 20 Ncm · Driver: 1.25 mm / 0.05" hex
Rosen Screw 1.4mm shown with its driver engagement and thread detail

Straight axial pressure on a fully seated hex is what protects the screw channel.

  1. 1

    Match the driver before anything else

    Confirm the bit is 1.25 mm / 0.05" hex and that it seats fully to the bottom of the socket. A driver that only half-engages will round the hex long before it reaches 20 Ncm.

  2. 2

    Start the thread by hand

    Engage the first threads with finger pressure on the driver. Crossing a thread at this stage costs a screw, on a multi-unit case, the whole seating sequence.

  3. 3

    Tighten to 20 Ncm with a calibrated wrench

    Apply straight axial pressure and stop at the 20 Ncm mark. Do not substitute an uncalibrated handpiece or estimate the torque by feel.

  4. 4

    Work the arch in sequence

    On full-arch multi-unit structures, torque in the order your protocol defines and re-check each screw after its neighbours are seated — seating one screw can relax the one beside it.

  5. 5

    Record the lot and the value

    Note the lot on the work order and the torque actually reached. If a screw is re-opened later, that record tells you whether the part or the protocol is at fault.

What over-torque actually does

Exceeding 20 Ncm deforms the hex socket first and the screw channel second. The product page describes a screw channel designed to resist deformation and fracture across repeated tightening cycles — that margin disappears the moment an undersized driver or an out-of-calibration wrench is used. If a driver slips, replace the screw rather than re-torquing it.

CAD/CAM Library Support for Digital Workflows

The product page states that library support is available for CAD/CAM design and planning. For a lab that designs full-arch and partial restorations, that is the difference between modelling the screw channel and guessing at it.

Rosen Screw 1.4mm screw geometry for digital design and planning

The product page covers both full-arch and partial implant restorations.

What to settle before the next design

  • Request the library files first. Do not model a screw channel from memory and correct it later in the workflow.
  • Carry the driver spec into the work order. The 1.25 mm / 0.05" hex requirement belongs on the lab ticket, not only in the catalogue.
  • Confirm the screw length in the design. The 1.4 mm designation is part of the SKU label — check it against the abutment you are designing onto.
  • Decide the route before the design freezes. A direct-to-MUA design has one fewer interface in the stack than a titanium-base design, and the file reflects that.

Labs that plan in CAD/CAM and seat chairside are the most sensitive to this: if the design assumes a Ti base and the box contains a direct-connect screw, the case stops on the bench. Confirm the route with the restoring clinician before the file is approved.

Match the Scenario to the Specification

Four situations account for most of the interest in this part. Each one turns on a different number from the specification sheet.

You stock one SKU across a mixed-brand catalogue

Specification that decides it: 26 listed platforms, one part number.

Decision: confirm your 1.25 mm hex driver seats on each platform you support before you commit to the 100-piece tier — the list is a starting point, not a bench test.

Check the specification →

Your lab runs full-arch bar cases

Specification that decides it: direct MUA connection with no Ti base, torqued to 20 Ncm.

Decision: validate one full case before you move the whole workflow off titanium bases — the component count changes, and so does the lab ticket.

View the product page →

A screw has stripped mid-appointment

Specification that decides it: the 1 Pc option at the low end of the $4.00 – $15.00 displayed range.

Decision: keep single pieces in stock for the platform you place most, and confirm the platform before substituting a screw from another brand’s kit.

Request single-unit supply →

You design in CAD/CAM before you seat

Specification that decides it: library support stated on the product page for design and planning.

Decision: request the library files and confirm the screw-channel geometry before the design is approved, not after the framework is milled.

Ask about digital workflow support →

Request a Quote, Bulk Pricing or a Compatibility Check

Labs, distributors and clinics ordering the 50 or 100-piece tier usually have one extra question attached — whether the part suits the platform they actually place. Send the platform name with the enquiry and the answer comes back with the quote.

What to include so the reply is useful

  • The platform you are fitting, taken from the 26-system list above.
  • The quantity tier you are considering: 1, 10, 50 or 100 pcs.
  • The driver size in your kit — it should read 1.25 mm / 0.05" hex.
  • Whether you need CAD/CAM library files for design and planning.
  • Whether the order is for a single clinic, a lab or distribution stock.

Bulk and repeat-order pricing is quoted against the quantity tier selected on the product page. Single-unit orders for chairside replacement can be placed directly from the product page.

Request a Quote

Related Reading

Three notes to help clarify product requirements before contacting the supplier.

What Is a Multi Unit Abutment Screw in Dental Implant Restorations

A multi unit abutment screw is easiest to understand as the small fastening part inside a multi-piece implant restoration, not as a complete product name on its own.

Read article

How Do You Read a Multi Unit Abutment Screw Listing?

A multi unit abutment screw listing is a search lead rather than a confirmed product identity, and the useful reading method is to separate the screw fastener from the abutment body before asking a…

Read article

Reading Dental Implant Abutment Listings Before a Professional Visit

A dental implant abutment listing can show a brand name, a millimeter figure, and a material word at the same time and still leave you unsure which of those details describe the part planned for your…

Read article

Frequently Asked Questions

what driver and torque does the rosen screw 1.4mm require?

it requires a 1.25 mm / 0.05" hex driver and is specified for 20 ncm torque. use a calibrated wrench and confirm the driver seats fully in the socket before tightening.

does this screw require a titanium base?

no. the rosen screw 1.4mm is designed to connect directly to the multi-unit abutment without a ti base, which removes one component from the restorative stack.

what material is the screw made from?

it is made from medical titanium gr5 eli.

which implant platforms are listed as compatible?

the product page lists 3i, adin, astra, blueskybio, dess, biohorizons, cortex, densply, dentis icx, gentek, zfx, hiossen, osstem, keystone, medentika, ips medentis medical (icx), megagen, neobiotech, neodent mini conical, nobel biocare, noris, southern implants, straumann, srl, thommen medical and zimmer. confirm driver seating on your platform before ordering.

what quantity options are available?

the screw is offered in 1 pc, 10 pcs, 50 pcs and 100 pcs options. the product page asks you to choose an option before adding to cart or buying now.

is cad/cam library support available for digital design?

yes. the product page states that library support is available for cad/cam design and planning, and the screw is described for full-arch and partial implant restorations.